Protec Equipment Resources
   Contact Us: 866.352.5550
    
blog-header

Recently Published Blogs

Rent the SKF Baker PP30, Extend the Testing Voltage Range of AWA-IV/12

by Protec Tech Team July 16, 2018

When coupled with SKF (Baker) 12kV Static Motor Analyzer AWA-IV/12  , the SKF Baker PP30 Power Pack extends the insulation testing voltage range.  The PP30 is ideal for use in manufacturing, predictive maintenance, motor rewind and repair settings. 

Contact Us Now

READ MORE >>

Can Using a Megger Meter be Destructive?

by Protec Tech Team July 16, 2018

Megger (insulation resistance tester) is a type of electrical test equipment used to verify the effectiveness of insulation to act as a barrier between energized conductors, or between energized conductors and ground. It is critical to the reliability of the electrical power system that there is a way to know when insulation has been damaged or compromised in any way.

Contact Us Now READ MORE >>

Choose the Megger Insulation Tester That is Right for You

by Protec Tech Team July 10, 2018

Contact Us NowTesting electrical insulation can be quick and easy when using test equipment specifically designed to perform insulation resistance measurements. A good insulator should have a very high resistance to current flow.  Factors such as temperature, electrical and mechanical stresses, weather and moisture ingress are all capable of adversely impacting the characteristic qualities of materials that make them such good insulators. The degradation of these materials over time can result in unplanned outages, safety concerns for personnel and an overall degradation of power system reliability.  

READ MORE >>

Avoid Dangerous Accidents by Conducting a Megger Insulation Test

by Protec Tech Team July 10, 2018

An insulation resistance test is conducted to examine the effectiveness of insulation in a variety of electrical power system apparatus. Faulty electrical insulation is the source of dangerous shock hazards and can often cause ancillary damage to adjacent equipment as well. Routine electrical testing and maintenance can help to identify when insulation has deteriated before it reaches the point of failure, saving the expense of repairs and unplanned outages. 

READ MORE >>

Testing Relays Using the Doble F2253 Relay Test Set

by Protec Tech Team July 05, 2018

Protective Relays could be characterized as circuit managers with varying degrees of supervisory and control capabilities depending on the complexity and criticality of the circuit.  They are designed to recognize abnormal or fault conditions, and to isolate the affected portion or the electrical system.  Not only does this allow the unfaulted portion of the electrical system to continue to function normally, but it diminishes the impact of the faulted portion of the system.  Changes to power system circuits and the coordination of protective devices can change due to age, loading, environmental impacts, new construction, etc. It is therefore critical that these devices function properly and are appropriately coordinated when they are called into action.

READ MORE >>

The Advantages of Sweep Frequency Response Analysis in Transformer Testing

by Protec Tech Team July 02, 2018

Sweep Frequency Response Analysis (SFRA) is an electrical testing method which identifies changes to the internal workings of a transformer.  The transformer is an electrical filter that has a specific response to each independent input frequency. The test equipment is used to apply a test voltage to a transformer over a range of frequencies. 

The output of the transformer is then monitored in relation to its corresponding input frequency.  The results, when graphed, make up a signature response, much like a unique fingerprint. The initial SFRA test will then become a baseline for comparison when future tests are performed.  When these signatures do not match the baseline signature, something has changed internal to the transformer and merits further investigation.   

READ MORE >>

The F2000 Series Doble Relay Test Sets

by Protec Tech Team June 25, 2018

Relays are often utilized in electrical facilities as isolated switches or protective devices for various electrical equipment. Due to the mechanical operation of relays, the contacts are prone to contact degradation, so it is important to regularly test for the electromechanical, electronic and protection schemes to ensure safe and reliable operation, and to avoid a faulty relay system acting up during critical operations. To assess relays and protections schemes, consider investing in a relay test set or a power system simulator.

READ MORE >>

How a DLRO Works

by Protec Tech Team June 25, 2018

A Digital Low Resistance Ohmmeter or DLRO is used to measure the resistance of circuit breaker contacts, welded joints, terminal connections and other bonded surfaces. The resistance measurements are sensitive enough to detect very small changes in test samples.  For example, they provide users with the ability to identify loose connections, corrosion or the presence of other contaminants. 

READ MORE >>

Rent the HV Diagnostics PD60-2 Partial Discharge Measurement System

by Protec Tech Team June 18, 2018

The PD60-2 is a portable two-piece partial discharge (PD) measurement and location system that interfaces to the following HV Diagnostics Test systems:

READ MORE >>

Does AC and DC Hipot Tests Cause Damage?

by Protec Tech Team June 18, 2018

Hipot testing is primarily performed to make sure that high voltage insulation will hold up during service. Many equipment and plant owners share concerns regarding the possibility for causing damage or premature deterioration of insulation by performing hipot testing on their assets.

READ MORE >>

Fully Analyze Circuit Breakers with the Vanguard CT-8000 S3

by Protec Tech Team June 05, 2018

The Vanguard CT-8000 S3 Digital Circuit Breaker Analyzer can fully analyze a circuit breaker's performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes.

Contact Us Now

The Vanguard CT-8000 S3 can perform dynamic-resistance tests using a 200-ampere, built-in, DC power supply. One channel is available for performing a dynamic contact resistance test. The resistance measuring range is from 1 micro-ohm to 1,999 micro-ohms.

READ MORE >>

Rent the Megger MWA330A 3-Phase TTR, Winding Resistance Analyzer

by Protec Tech Team June 05, 2018

The Megger MWA330A 3-Phase Transformer Turns Ratio and Winding Resistance Analyzer is an advanced 3-phase transformer test system that provides complete ratio, phase and winding resistance measurements with only one 3-phase lead-set connection.

Contact Us Now

Once connected, the Megger MWA330A performs DC resistance measurements on all high- and low-side windings without reconnection. It has an 8-terminal/6-winding resistance measurement capability and doesn’t need any inter-connected boxes, allowing for testing on all 6 windings without having to disconnect and reconnect leads.

READ MORE >>
Bolt-Rule-b.jpg

Protec Equipment Resources Inc.
National Headquarters
1517 West Carrier Pkwy
Suite 116
Grand Prairie, Texas 75050

Phone: 972.352.5550
Fax: 972.352.5553

Become a Protec Insider